Zimmer versys hip system surgical technique book

Zimmer orthopaedic surgical products dover, ohio medical. Versys beaded fullcoat revision hip prosthesis surgical. The taperloc hip system from biomet has led the competition in design and longevity for over 20 years. The system offers the versatility of three minimally invasive mis instrumentation options. Trial implant select and assemble the stem trial with the chosen neck style and length. Versys fiber metal taper hip prosthesis zimmer biomet. The range of shapes and sizes provide an option to fit nearly any patient. The morphology of the metal surface is a design feature of cemented femoral components that needs to be considered together with the other implant design features, surgical technique variables, and patient factors to ensure the overall appropriateness of an implant in a particular surgical setting. Templating for the zmr revision hip system preoperative planning for the insertion of the zmr revision hip system femoral component requires at least two views of the involved femur.

Joe dean krack and gerald krack filed suit in federal court in new orleans against zimmer inc. Zimmer fluid waste management family zimmer surgical. Zimmer preference cci surgical technique zimmer preference cci surgical technique intro section page 10 step 10. The interface and workflow of the achievecas system. Jan 04, 2017 the variability of femoral canals ie dorr classification prevents a single stem design from truly standing out. Intro zimmer segmental system distal femoral surgical technique intro. Zmr hip system surgical technique using the cone proximal body component and the tapered distal stem also includes preparation for a bowed poroussplined distal stem hcp content posted april 19, 2011 in surgical techniques. Versys fiber metal taper hip prosthesis surgical zimmer versys fiber metal taper hip prosthesis surgical technique. The zimmer unicompartmental uni knee high flex knee system the zimmer uni high flex knee is an advanced partial knee replacement thats designed for those who need joint replacement but only have damage on one sideor compartmentof their knee and. Metaphyseal and diaphyseal bone is intact, providing good bone for structural support and implant fixation. None of the equipment posted for sale on is owned by medwow, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page. Manufacturer narrative no devices, xrays or photos were recd. All images in this technique guide depict an open tlif procedure for image clarity. This specific procedure pack addresses distal radius fractures, and features the.

Knee system has longterm clinical success with 98% survivorship over a 610 year period. Versys fiber metal taper hip prosthesis zimmer biomet pdf book online select one of servers for direct link. The taperset hip system is designed for total or partial hip arthroplasty and is intended to be used with compat ible components of the consensus hip system. The following technique is intended solely as a general guide for shoulder joint replacement with the biangular shoulder system. This surgical technique will guide you through the software and instrument workflow for an achievecas hip arthroplasty. Expandable tlif and plif technology surgical technique. Metaphyseal and diaphyseal bone is intact, providing good bone for. However, it is recommended a posterior approach to the hip. Controlling fluid and smoke waste in your or is important for the safety of your staff. The manufacturer promotes several hip products that use zimmer trabecular. This is for a zimmer versys hip system orthopedic instruments 500144 1 44mm 500145. New zimmer versys hip system orthopedic instruments.

Acetabular components including the trilogy acetabular hip system and the durom cup. Zimmer dental provides a comprehensive portfolio of innovative implant technologies designed to meet a. This system has been engineered to add value by addressing the productivity needs of the operating room in one complete package. Versys beaded fullcoat revision hip prosthesis surgical technique.

Biomet, as the manufacturer of this device, does not practice medicine and does not recommend this or any other surgical technique for use on a specific patient the surgeon who performs only implant procedure is responsible for determining and utilizing the. Fiber metal taper hip prosthesis surgical technique 1 versys fiber metal read. Zimmer biomet holdings zmh divisions, quarterly segment. Zimmer is a medical device company that creates a variety of orthopedic implants. Surgical technique there are three different bone plates 6, 8, 10 hole. Kinectiv technology facilitates surgical exposure in the minimally invasive approach as the neck is not inserted until the trial. Manufacturer specifications versys total hip system, zimmer please note. The goals of a minimally invasive surgical procedure are to. They claim that the artificial hip joe dean received in july 2005 was faulty, causing him pain, weakness and disability due to a problem with the femoral head. The surgical technique will vary somewhat depending on the individual clinical situation. If using a versys trial head, refer to the zimmer versys trial head surgical technique 97801800100 for additional information.

Versys fiber metal taper hip prosthesis surgical technique. Zimmer s fluid waste management solution lets you control everything you expect from suction to financing. I spend time providing technical support via phone and email to customers on the same equipment. An important component of the system is trabecular metal technology, available exclusively from zimmer. Sep 26, 2011 miniincision hip posterolateral approach surgical technique using versys fiber metal taper hip prosthesis, trilogy acetabular system, and hemovac wound drainage device hcp content posted september 26, 2011 in surgical techniques.

Zmr hip system surgical technique zimmer biomet tv. Preservation of the abductor muscle insertion ensures normal. Are you a surgeon interested in access to the surgeon portal. Taperloc hip system zimmer biomet books taperloc hip system zimmer biomet. Surgical technique hip system consensus orthopedics. The segmental distal femoral component features the same condylarloading geometry as the zimmer nexgen rotating hinge knee rh knee. Zimmer cementless versys orthopaedicsone device reference. The continuum hip system offers a wide range of options to allow your surgeon to customize your hip replacement to meet your individual needs. Surgical technique this brochure describes the surgical technique used by richard l. The remaining steps in this surgical technique are similar in both open and minimally invasive surgical approaches. Assemble the stem and stem inserter, then attach the distal centralizer. Cemented femoral component surface finish mechanics. Versys mt hip system fiber metal midcoat stems are manufactured from tivanium ti6ai4v alloy, feature a proximal porous surface of.

Versys beaded fullcoat revision hip prosthesis surgical technique 4 fig. Zimmer psi persona knee surgical technique trabecular metal acetabular restrictor and augment surgical technique versafx femoral fixation system surgical technique for fixation of intertrochanteric fractures of the femur. Find zimmer new in the box versys hip endo and femoral systems of various sizes. Trilogy abtm acetabular system free html5 flip book. Zimmer versys total hip system prosthesis, joint, hip. The system utilizes one cone collar provisional for two rasp sizes e. The design type determines the area of the femoral canal where fixation occurs and the surgical technique required for implantation. The individual cables may be inserted before or after the plate is attached to the bone. The cone collar provisionals replicate the collarneck geometry of the femoral component for exact trial reductions. Zimmer execs talk 1st quarter sales, markets and biomet.

The versys hip system, a zimmer flagship brand, is supported by a common instrumentation set and is an innovative, integrated family of hip products that offers surgeons designspecific options to meet varying surgical philosophies and patient needs. Zimmer segmental system distal femoral surgical technique. The acquisition made the new company the secondlargest manufacturer in the orthopedic market. Joint replacement implants are not onesize fits all. Many of zimmers products are metal components and its revision systems are metalonmetal mom, which means both the femoral head and acetabular lining are made of metal. I have become familiar with sap software and eetime through exposure on the job at zimmer surgical. The zimmer unicompartmental uni knee high flex knee system the zimmer uni high flex knee is an advanced partial knee replacement thats designed for those who need joint replacement but only have damage on one sideor compartmentof their knee and are no longer as active as they once were because of pain. This approach provides excellent exposure without disruption of the abductor muscles. The increased vision from the achievecas system advances and strengthens minimally invasive surgery. Please refer to the stryker retractor system surgical technique guides, including luxor, phantom, and. What are the problems with the zimmer versys hip replacement system. Taperloc hip system hip zimmer biomet summit surgical. At this time, make a surgical evaluation of the sleeve in relation to its final position. Trabecular metal technology is not a coating, like the surface of many hip replacements.

The goal is for bone to incorporate into the implant. The versys epoch fullcoat hip stems are designed to fit the unique variations in female and male hip anatomies. Miniincision hip posterolateral approach surgical technique. The zimmer versys hip replacement system is a total hip replacement system with 3 components. Zimmers fluid waste management solution lets you control everything you expect from suction to financing. I spend time troubleshooting and repairing medical equipment manufactured by zimmer surgical. All trademarks herein are the property of biomet, inc. Zimmer also has complete hip revision systems, such as the wagner sl revision hip. The heads are offered in 28 and 32mm diameters and threeneck lengths each. The interface and workflow of the achievecas system are extraordinarily simple and userfriendly.

Lawsuit filed against artificial hip manufacturer righting. The variability of femoral canals ie dorr classification prevents a single stem design from truly standing out. Implantation insert the medullary plug, prepare the canal, and introduce bone cement in a retrograde fashion while pressurizing. The standard stem line is based on the proven clinical results of the versys porous hip system and the epoch hip prosthesis 1, 2, 5. Significantly impaired joints resulting from rheumatoid, osteo, and posttraumatic arthritis. The trilogy ab ceramiconceramic articulation system will be implanted with thefollowing commercially available zimmer femoral stems. Surgical technique 5 incision 5 exposure of the hip joint 5 determination of leg length 5 osteotomy of the femoral neck 5 preparation of the femur 7 intramedullary reaming optional 8 attachment of the rasp alignment tip optional 10 femoral rasping 10 trial reduction 11 insertion of the femoral component 12 attachment of the femoral head 12. To request access, complete the following information. Components, versys hip system 1214 heads and the legacy 1214 heads fig.

1088 1222 1432 1606 573 992 715 338 744 684 1085 589 186 1300 134 1390 581 996 813 70 37 203 1413 25 391 1010 1300 507 711 212 1360 511 1499 372 1022